ARC Fire Stop Strip can be manufactured up to 50mm thickness and in widths from 100mm upwards.
ARC Fire Stop Strip is designed to prevent the passage of smoke and flames through narrow voids in the construction, offering up to four hours fire integrity when installed between masonry or concrete. Possible applications include: top of masonry walls under the soffit, above partitions, expansion joints, and between ceilings and walls.
Length supplied | 1.2m |
Third-party certification | IFC certificate number: IFCC 1732 |
Insulation | Non-combustible rockfibre mineral wool insulation |
Thermal conductivity | 0.035W/mK |
Fire rating | Up to four hours |
Test standard | EN1366-4 |
Construction type | Masonry |
Orientation | Horizontal or vertical |
What’s the maximum size you can manufacture ARC Fire Stop Strip for?
ARC Fire Stop Strip can be manufactured up to 50mm thickness and in widths from 100mm upwards.
Can ARC Fire Stop Strip be used as a joint seal?
ARC Fire Stop Strip can be used to provide fire stopping for gaps in masonry/concrete constructions up to 50mm, provided there is a minimum 100mm depth.
ARC Fire Stop Slab provides up to two hours fire integrity horizontally or vertically within external masonry walls, ideal for use at separating floor levels.
Product detailsARC Cavity Stop Sock restricts the spread of smoke and flames within the cavity of external masonry walls.
Product detailsARC Eco-Closer closes the cavity around window and door openings in masonry walls, providing up to 60 minutes fire integrity.
Product details