Added Fire Stop Slab to your list of saved products. View saved products

High Rise Solutions

High Rise Solutions

Cavity Fire Barriers for High Rise Construction

Typical applications

Masonry construction:

Vertical party wall:

ARC Fire Stop Slab
Closed state cavity fire barrier

Horizontal separating floor:

ARC Fire Stop Slab
Closed state cavity fire barrier

External non-combustible rainscreen cladding:

Vertical party wall:

ARC Fire Stop Slab
Closed state cavity fire barrier

Horizontal separating floor:

ARC Open State Cavity Barrier
Open state ventilated intumescent cavity fire barrier

 

Open State Cavity Barrier

Open State Cavity Barrier

ARC Open State Cavity Barrier provides fire stopping within the cavity of external walls where ventilation is required in service use. Manufactured from non-combustible rockfibre mineral wool with a reactive intumescent layer. The intumescent layer will rapidly expand when exposed to heat in a fire event, closing off the air gap and preventing vertical fire spread within the external wall cavity.

  • Offers up to 120 minutes fire integrity
  • Suitable for use with either concrete or masonry internal and external substrates
  • Manufactured from non-combustible rockfibre mineral wool with a reactive intumescent layer
  • Provides an air gap of up to 25mm or 44mm
  • Tested to ASFP TGD19 Fire Test Standard

Installation Video

Fire Stop Slab

ARC Fire Stop Slab provides fire stopping within the cavity of external masonry walls. Manufactured from rockfibre mineral wool insulation with a class ‘O’ reinforced aluminium foil facing to both sides offering excellent resistance tosmoke.

  • Up to three hours fire integrity
  • Foil faced to provide a smoke barrier
  • Suitable for horizontal or vertical applications
  • Cut to size on site or factory finished
  • Available to suit cavity widths up to 450mm
  • Third-party certificated by IFC

Products in the High Rise Solutions System

Open State Cavity Barrier

Fire product

Open State Cavity Barrier

ARC OSCB cavity barriers are designed for installation within cavities where ventilation is required in service use.

Product details

Fire product

Fire Stop Slab

ARC Fire Stop Slab provides up to two hours fire integrity horizontally or vertically within external masonry walls, ideal for use at separating floor levels.

Product details